SECTION: 08 14 00 WOOD DOORS
Criteria
- Quality Assurance: EP 415-1-261, Volume 3
- UFGS SECTION 08 14 00 WOOD DOORS
- NFPA 80 Fire Doors and Windows
- NFPA 101 Life Safety Code
- NWWDA I.S.1-A Architectural Wood Flush Doors
- Manual for Maintenance and Repair For Historic Structures
- Resource Conservation and Recovery Act (RCRA) , Section 6002
- Farm Security and Rural Investment Act of 2002, Section 9002
- Federal Sustainable Acquisition Items/Requirements
- DoD Green Procurement Policy (Aug 27 2004)
- DoD Green Procurement Strategy (Nov 2008)
- Army Green Procurement Policy (Nov 22 2006)
- Federal Acquisition Regulation, Part 23
- USDA BioPreferred Program
- EPA Final Guidance on Environmentally Preferable Purchasing
- HJB Form 225 (JBLM Sustainable Acquisition Exception Form)
- UFC 1-200-2 (High Performance and Sustainable Buildings Requirements)
- ASA IE&E Sustainable Design and Development Policy (Jan 17 2017)
- 10 CFR 436 Subpart A (Life Cycle Cost Analysis, Energy- and -Water Related Projects)
- NIST 135 (Life Cycle Cost Analysis, Energy- and -Water Related Projects)
- OMB Circular A-94 (Life Cycle Cost Analysis, Non-Energy and -Water Related Projects)
- Tri-Services MOA (Life Cycle Cost Analysis, MILCON)
Changes or Criteria Notes to Unified Facilities Guide Specifications (UFGS)
Paragraph # and Title (if any) |
Note to Designer |
Change Text |
1.2 SUBMITTALS
SD-03 Product Data
Doors
|
Add the following for historic buildings: |
For historic buildings, product data submittals for doors must be approved by Cultural Resource Manager, PW-ED, BLDG 2012, RM 307, 253-966-1785. |
1.2 SUBMITTALS |
If 01 33 29 is not incorporated in the specifications, change reference to 01 33 29 in this section to instead say 01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS and ensure the additional sustainable acquisition language is included within that section. |
|
|
Under SD-11, add the following if interior adhesives and/or sealants will be field applied (vs factory applied). Also ensure there are VOC and applicable recycled/biobased content submittal requirements for any field applied paints and coatings at 09 90 00: |
Interior Adhesives and Sealants (VOC Content); S
Wood Sealants (Biobased Content); S
|
1.2 SUBMITTALS |
With the exception of the warranty submittal, ensure all the submittals under SD-11 of the UFGS (to include the added submittal for interior adhesives and sealants above) are also included under "SD-01 Preconstruction Submittals" to ensure the Government can verify that proposed materials comply with legal and policy requirements prior to work starting. |
|
2.1 PRODUCT SUSTAINABILITY CRITERIA |
Delete "For products in this section, where applicable and to extent allowed by performance criteria, provide and document the following:" The language at 01 33 29/01 57 19.01 20 allows for exceptions based on performance criteria, as long as adequate justification per the applicable legal or policy requirement is provided on HJB Form 225. |
|
2.1.1 CERTIFIED SUSTAINABLY HARVESTED WOOD |
[NOTE: In the column to the right, select 01 33 29 when it is incorporated into the specifications, otherwise select 01 57 19.01 20 and ensure it includes added sustainable acquisition language]
Revise language as follows:
|
Provide products and documentation in accordance with Section [01 33 29 SUSTAINABILITY REPORTING][01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS] paragraph SUSTAINABLY CERTIFIED WOOD. |
2.1.2 RECYCLED CONTENT FOR WOOD DOORS |
[NOTE: In the column to the right, select 01 33 29 when it is incorporated into the specifications, otherwise select 01 57 19.01 20 and ensure it includes added sustainable acquisition language]
Change title to "Recycled Content" and revise the language as follows:
|
Provide products and documentation in accordance with Section [01 33 29 SUSTAINABILITY REPORTING][01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS] paragraph RECYCLED CONTENT. For more information see https://sftool.gov/greenprocurement/green-products/1/construction-materials/22/building-insulation/0?addon=False and https://www.epa.gov/smm/comprehensive-procurement-guideline-cpg-program. |
2.1.3 REDUCE VOLATILE ORGANIC COMPOUNDS (VOC) (LOW EMITTING MATERIALS) FOR PRODUCTS |
[NOTE: In the column to the right, select 01 33 29 when it is incorporated into the specifications, otherwise select 01 57 19.01 20 and ensure it includes added sustainable acquisition language]
Revise language as follows:
|
Provide products and documentation in accordance with Section [01 33 29 SUSTAINABILITY REPORTING][01 57 19.01 20 SUPPLEMENTAL TEMPORARY ENVIRONMENTAL CONTROLS] paragraph REDUCE VOLATILE ORGANIC COMPOUNDS (VOC) (LOW EMITTING MATERIALS). |
2.1.4 BIO-BASED PRODUCTS |
[NOTE: In the column to the right, select 01 33 29 when it is incorporated into the specifications, otherwise select 01 57 19.01 20 and ensure it includes added sustainable acquisition language]
If wood sealants will be factory applied, add this section and include the following language:
|
Provide products and documentation in accordance with Section [01 33 29 SUSTAINABILITY REPORTING][01 57 19.01 20 TEMPORARY ENVIRONMENTAL CONTROLS] paragraph BIO-BASED PRODUCTS. For more information, see https://sftool.gov/greenprocurement/green-products/1/construction-materials/1263/wood-concrete-sealers/0?addon=False. |
2.3.3 Weather stripping |
Add the following for historic buildings. |
Do not install felt weather stripping, as it retains moisture near the wood. Avoid vinyl, foam and surface mounted type weather stripping. |
Design Requirements
- Where new or replacement doors are required at buildings in the Joint Base Lewis-McChord Historic District, designers shall refer to "Maintenance and Repair Manual For Historic Structures at Fort Lewis, Washington", Section 6.0. Doors replaced or added in structures within the Joint Base Lewis-McChord Historic District must conform as closely as possible in materials and appearance to those existing (see attached sketches for examples). Specify solid wood, panel type doors wherever possible. Any glazed areas should be wood-stopped, with muntins providing true divided lites where glazing occurs.
- Any repairs to existing wood doors to remain must be made carefully. A historic color analysis may be directed by PW before any paint removal. The designer is also reminded of the likelihood of lead in old paint coatings. The specification should identify this probability and refer the contractor to the appropriate specification section for abatement. Remove old paint with scraper, hot air gun or chemical strippers. Do not use open flame. Repaint only sound wood (See UFGS 08612 for wood restoration techniques). Do not install felt weather stripping, it retains moisture near the wood. Avoid vinyl, foam and surface mounted type weather stripping.
- New wood doors on Joint Base Lewis-McChord shall primarily be 1�" thick, 7'-0" high, 5-ply, flush, solid core units. Doors shall be paint grade except for special applications. Doors to receive paint finish shall be economy grade, doors receiving natural finish shall be custom grade, birch veneer. Doors shall be rated as and where required by Fire Codes.
Notes to Designers on Drawing Content
Provide door schedule showing door number (keyed to Room number), size and thickness, door type, material, finish fire label requirement, hardware set number, and door frame callouts. Provide Sketches showing door and frame type elevations. Provide door head, jamb and sill details as required. If a specific door manufacturer/model is called out, add a note stating "or equivalent, the manufacturer and model are indicated only to show design intent and there is no intent to limit the selection of similar products of other manufacturers.
Standard Details
Applicable Points of Contact
Design Standards