SECTION: 04 21 13.13 NONBEARING MASONRY VENEER/STEEL STUD WALLS
Criteria
- UFGS SECTION 04 21 13.13 NONBEARING MASONRY VENEER/STEEL STUD WALLS
- Resource Conservation and Recovery Act (RCRA) , Section 6002
- Federal Sustainable Acquisition Items/Requirements
- DoD Green Procurement Policy (Aug 27 2004)
- DoD Green Procurement Strategy (Nov 2008)
- Army Green Procurement Policy (Nov 22 2006)
- Federal Acquisition Regulation, Part 23
- EPA Final Guidance on Environmentally Preferable Purchasing
- HJB Form 225 (JBLM Sustainable Acquisition Exception Form)
- UFC 1-200-2 (High Performance and Sustainable Buildings Requirements)
- Army Sustainable Design and Development Policy
Changes or Criteria Notes to Unified Facilities Guide Specifications (UFGS)
Paragraph # and Title (if any) |
Note to Designer |
Change Text |
|
The UFGS cancelled this section in 2015. Language is now incorporated at 04 20 00. Only use this section for older contracts that incorporated 04 21 13.13 in their specifications. For any other contracts, including new ones, use 04 20 00. Only previously existing information has been updated below to remain current. |
|
1.2 SUBMITTALS |
If 01 33 29 is not incorporated in the specifications, change reference to 01 33 29 in this section to instead say 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS and ensure the additional sustainable acquisition language at paragraphs 1.3 and 1.7 of 01 57 19 is included within that section. |
|
1.2 SUBMITTALS |
[NOTE: In the column to the right, select 01 33 29 when it is incorporated into the specifications, otherwise select 01 57 19 and ensure it includes the added sustainable acquisition language at paragraphs 1.3 and 1.15]
Add the following under "SD-01 Preconstruction Submittals" and SD-11 "Closeout Submittals":
|
Concrete and Cement (Recycled Content); S |
1.2 SUBMITTALS |
At SD-01, add any necessary submittals to verify compliance with the low emission requirements in ASHRAE Standard 189.1, section 8.4.2 or 8.5.2 (for materials inside the weatherproofing). See also UFC 1-200-02. |
|
2.1 VENEER WYTHE |
Add the following sentences to the paragraph: |
Any Mortar or grout used in masonry construction for repairs or modifications to structures within the Joint Base Lewis-McChord Historic District which is exposed to view shall be tinted so as to approximate the color of an adjacent mortar or grout on the building. See Manual Section "Restoration and Cleaning of Masonry in Historic Structures" for further guidance. |
2.1.2 CONCRETE MASONRY UNIT |
[NOTE: In the column to the right, select 01 33 29 when it is incorporated into the specifications, otherwise select 01 57 19 and ensure it includes the added sustainable acquisition language at paragraphs 1.3 and 1.15]
Add the following:
|
Materials shall conform to recycled content requirements in accordance with paragraph RECYCLED CONTENT in Section [01 33 29 SUSTAINABILITY REPORTING][01 57 19 ENVIRONMENTAL PROTECTION]. Note that slag content may be environmentally preferable to coal derivatives in accordance with FAR 23.7. |
2.1.3 PREFACED CONCRETE MASONRY UNIT |
[NOTE: In the column to the right, select 01 33 29 when it is incorporated into the specifications, otherwise select 01 57 19 and ensure it includes the added sustainable acquisition language at paragraphs 1.3 and 1.15]
Add the following:
|
Materials shall conform to recycled content requirements in accordance with paragraph RECYCLED CONTENT in Section [01 33 29 SUSTAINABILITY REPORTING][01 57 19 ENVIRONMENTAL PROTECTION]. Note that slag content may be environmentally preferable to coal derivatives in accordance with FAR 23.7. |
Design Requirements
Notes to Designers on Drawing Content
Standard Details
Applicable Points of Contact
Design Standards